Mains Units

three-phase motor, IE1

RN 100b6

uprated

  • 2.2Power, kW
  • 915Speed, rpm
  • 6Poles
  • 100IEC frame
  • 5.7Amps at 400 V
Nicolini three-phase motor

Specification

Rated output
2.2 kW
Speed
915 rpm (6-pole)
Supply
230/400 V 50 Hz, three-phase. Also wound for 60 Hz and other voltages to order; the figures here are at 50 Hz.
Current at 400 V
5.7 A
Efficiency
74%, IE1
Power factor
0.77
Starting current
5 × rated
Torque
22 Nm
Frame
IEC 100
Shaft end
28 × 60 mm
Large flange (B5)
FF215
Small flange (B14)
FT130
Weight (B3)
23 kg

Uprated: Nicolini mark this power as one IEC does not list for the frame. It gives more power in a smaller frame, at lower efficiency.

Pumps it drives

No pump here has this motor as its first match.

Flanges and couplings

For an IEC 100 frame with a 28 mm shaft, bolting to the small flange (B14). Pick the one made for your pump series.

Part numberDescriptionFor pump series
1.099-529.0Hawk motor flange, IEC 100/112 B14NHDP Car Wash, NHDP 120, NHDP 150, NHDP 200, NHDP Chemical, NHDP Stainless Steel Chemical
1.099-530.0Hawk motor flange, IEC 100/112 B14NMT, NPM, NMT Car Wash, NMT High Temperature, NMT Nickel-Plated, NPM Nickel-Plated, NLTI, NMT - Car Wash Heavy Duty, NMT Chemical, NMT Stainless Steel Chemical, CHD 200, CHS 120
A08Udor motor flange A08, IEC 100/112 B3/B14, up to 4 kWA, AK, AWT
BC04Udor motor flange BC04, IEC 100/112 B3/B14, up to 4 kWB, BS, BCW, BWT, BK, C, CS, CWT, CK, CX, CH
P05Udor motor flange P05, IEC 100/112 B3/B14, up to 4 kWPN, PS
ZF044Interpump motor flange, IEC 100/112 B14E1, SS1, 44, 58VHT, E2 and C2W
ZF091Interpump motor flange, IEC 100/112 B1449, 50 and 51
ZF151Interpump motor flange, IEC 100/112 B1447, 47VHT, 66, 66VHT, 66SS, E3, C3W and SS3
1.099-541.0Hawk flexible coupling, IEC 100/112, 28 mm motor to 24 mm pumpNMT, NPM, NMT Car Wash, NMT High Temperature, NMT Nickel-Plated, NPM Nickel-Plated, XLTI, XLTI High Temperature, NLTI, XLTI Atex, NMT - Car Wash Heavy Duty, NMT Chemical, NMT Stainless Steel Chemical, CHD 200, CHS 120
1.099-543.0Hawk flexible coupling, IEC 100/112, 28 mm motor to 24 mm pumpNHDP Car Wash, NHDP 120, NHDP 150, NHDP 200, NHDP Chemical, NHDP Stainless Steel Chemical
ZG044Interpump flexible coupling, IEC 100/112, 28 mm motor to 24 mm pumpE1, SS1, 44, 58VHT, E2 and C2W
ZG091Interpump flexible coupling, IEC 100/112, 28 mm motor to 24 mm pump49 and 50
ZG151Interpump flexible coupling, IEC 100/112, 28 mm motor to 24 mm pump47, 47VHT, 66, 66VHT, 66SS, E3, C3W and SS3
ZGWW94Interpump flexible coupling, IEC 100/112, 28 mm motor to 24 mm pump51

Starter

Iskra parts for a direct-on-line starter at 400 V. Choose the contactor coil to match your control voltage.

Contactor

KNL9 contactors, rated 4 kW AC-3 at 400 V

CoilTypeIskra codeSuppliers
24 V AC B7KNL9-01 1NC030050615000 
24 V AC B7KNL9-10 1NO030050616000 
42 V AC D7KNL9-01 1NC030050633000 
42 V AC D7KNL9-10 1NO030050634000 
48 V AC E7KNL9-01 1NC030050635000 
48 V AC E7KNL9-10 1NO030050636000 
110-125 V AC F7KNL9-01 1NC030050637000 
110-125 V AC F7KNL9-10 1NO030050638000 
208 V ACKNL9-01 1NC030050819000 
220-240 V AC M7KNL9-01 1NC030050475000 
220-240 V AC M7KNL9-10 1NO030050474000 
380-415 V AC Q7KNL9-01 1NC030050639000 
380-415 V AC Q7KNL9-10 1NO030050640000 
440-460 V AC R7KNL9-10 1NO030050919000 
480-520 V AC S7KNL9-01 1NC030050641000 
480-520 V AC S7KNL9-10 1NO030050642000 

Overload protection

Set to the motor's full-load current, 5.7 A.

Other motors in this range

RN 63a6RN 63b6RN 71a6RN 71b6RN 71c6RN 80a6RN 80b6RN 90La6RN 90Sa6RN 100a6RN 112a6RN 112b6RN 132Ma6RN 132Mb6RN 132Sa6RN 160La6RN 160Ma6RN 180La6RN 200a6RN 200b6