Nicolini motors, three-phase 230/400 V and single-phase 230 V, with their 50 Hz figures. A 1450 rpm pump takes a 4-pole motor and a 1000 rpm pump a 6-pole one, of at least the power the pump absorbs. On 60 Hz mains the same motors run about a fifth faster: a 4-pole motor turns a 1750 rpm pump. Nicolini wind them for 60 Hz and other voltages to order.
| Picture | Type | kW | rpm at 50 Hz | Frame | Class | A at 400 V | Drives |
|---|---|---|---|---|---|---|---|
| RN 63a2 | 0.18 | 2740 | IEC 63 | IE1 | 0.47 | 4 pumps | |
| RNM 63a2 | 0.18 | 2780 | IEC 63 | Single-phase | 1.3 at 230 V | 4 pumps | |
| RN 63b2 | 0.25 | 2760 | IEC 63 | IE1 | 0.65 | 0 pumps | |
| RNM 63b2 | 0.25 | 2780 | IEC 63 | Single-phase | 1.65 at 230 V | 0 pumps | |
| RN 63c2 uprated | 0.37 | 2760 | IEC 63 | IE1 | 0.97 | 0 pumps | |
| RN 71a2 | 0.37 | 2810 | IEC 71 | IE1 | 1 | 0 pumps | |
| RNM 71a2 | 0.37 | 2800 | IEC 71 | Single-phase | 2.7 at 230 V | 0 pumps | |
| RN 71b2 | 0.55 | 2800 | IEC 71 | IE1 | 1.4 | 0 pumps | |
| RNM 71b2 | 0.55 | 2820 | IEC 71 | Single-phase | 3.9 at 230 V | 0 pumps | |
| RN 71c2 uprated | 0.75 | 2790 | IEC 71 | IE1 | 1.9 | 2 pumps | |
| RN 80a2 | 0.75 | 2800 | IEC 80 | IE1 | 1.7 | 2 pumps | |
| RNE 80a2 | 0.75 | 2910 | IEC 80 | IE3 | 1.7 | 2 pumps | |
| RNM 80a2 | 0.75 | 2850 | IEC 80 | Single-phase | 5.8 at 230 V | 2 pumps | |
| RN 80b2 | 1.1 | 2820 | IEC 80 | IE1 | 2.4 | 4 pumps | |
| RNE 80b2 | 1.1 | 2870 | IEC 80 | IE3 | 2.4 | 4 pumps | |
| RNM 80b2 | 1.1 | 2800 | IEC 80 | Single-phase | 7.5 at 230 V | 4 pumps | |
| RNM 90Sa2 | 1.3 | 2860 | IEC 90S | Single-phase | 8.82 at 230 V | 0 pumps | |
| RN 80c2 uprated | 1.5 | 2810 | IEC 80 | IE1 | 3.5 | 6 pumps | |
| RN 90Sa2 | 1.5 | 2860 | IEC 90S | IE1 | 3.2 | 6 pumps | |
| RNE 90Sa2 | 1.5 | 2875 | IEC 90S | IE3 | 3 | 6 pumps | |
| RNM 80c2 | 1.5 | 2750 | IEC 80 | Single-phase | 9.5 at 230 V | 6 pumps | |
| RNM 90Sb2 | 1.5 | 2860 | IEC 90S | Single-phase | 10.2 at 230 V | 6 pumps | |
| RN 90Sb2 uprated | 1.85 | 2860 | IEC 90S | IE1 | 3.95 | 5 pumps | |
| RNM 90La2 | 1.85 | 2840 | IEC 90L | Single-phase | 12.5 at 230 V | 5 pumps | |
| RN 90La2 | 2.2 | 2890 | IEC 90L | IE1 | 4.7 | 35 pumps | |
| RNE 90La2 | 2.2 | 2880 | IEC 90L | IE3 | 4.6 | 35 pumps | |
| RNM 100a2 | 2.2 | 2880 | IEC 100 | Single-phase | 14 at 230 V | 30 pumps | |
| RNM 90Lb2 | 2.2 | 2820 | IEC 90L | Single-phase | 13.1 at 230 V | 30 pumps | |
| RN 100a2 | 3 | 2880 | IEC 100 | IE1 | 6.2 | 45 pumps | |
| RN 90Lb2 uprated | 3 | 2890 | IEC 90L | IE1 | 6.3 | 45 pumps | |
| RNE 100a2 | 3 | 2900 | IEC 100 | IE3 | 5.6 | 45 pumps | |
| RN 100b2 uprated | 4 | 2850 | IEC 100 | IE1 | 8 | 92 pumps | |
| RN 112a2 | 4 | 2895 | IEC 112 | IE1 | 7.8 | 92 pumps | |
| RNE 112a2 | 4 | 2910 | IEC 112 | IE3 | 7 | 92 pumps | |
| RN 112b2 uprated | 5.5 | 2870 | IEC 112 | IE1 | 11 | 75 pumps | |
| RN 132Sa2 | 5.5 | 2910 | IEC 132S | IE1 | 11.1 | 75 pumps | |
| RNE 132Sa2 | 5.5 | 2920 | IEC 132S | IE3 | 10 | 75 pumps | |
| RN 112c2 uprated | 7.5 | 2860 | IEC 112 | IE1 | 15.5 | 37 pumps | |
| RN 132Sb2 | 7.5 | 2900 | IEC 132S | IE1 | 14.8 | 37 pumps | |
| RNE 132Sb2 | 7.5 | 2910 | IEC 132S | IE3 | 13.1 | 37 pumps | |
| RN 132Ma2 uprated | 9.2 | 2920 | IEC 132M | IE1 | 18 | 15 pumps | |
| RN 132Mb2 uprated | 11 | 2920 | IEC 132M | IE1 | 20.9 | 4 pumps | |
| RN 160Ma2 | 11 | 2930 | IEC 160M | IE1 | 21.9 | 19 pumps | |
| RNE 160Ma2 | 11 | 2950 | IEC 160M | IE3 | 19.7 | 19 pumps | |
| RN 160Mb2 | 15 | 2920 | IEC 160M | IE1 | 29 | 2 pumps | |
| RNE 160Mb2 | 15 | 2940 | IEC 160M | IE3 | 26.7 | 2 pumps | |
| RN 160La2 | 18.5 | 2930 | IEC 160L | IE1 | 37.8 | 0 pumps | |
| RNE 160La2 | 18.5 | 2950 | IEC 160L | IE3 | 33 | 0 pumps | |
| RN 160Lb2 uprated | 22 | 2920 | IEC 160L | IE1 | 43 | 0 pumps | |
| RN 180Ma2 | 22 | 2930 | IEC 180M | IE1 | 41.7 | 0 pumps | |
| RN 180La2 uprated | 30 | 2945 | IEC 180L | IE1 | 56.5 | 0 pumps | |
| RN 200a2 | 30 | 2955 | IEC 200 | IE1 | 54 | 0 pumps | |
| RN 200b2 | 37 | 2950 | IEC 200 | IE1 | 65.4 | 0 pumps | |
| RN 63a4 | 0.12 | 1345 | IEC 63 | IE1 | 0.44 | 4 pumps | |
| RN 63b4 | 0.18 | 1375 | IEC 63 | IE1 | 0.63 | 0 pumps | |
| RNM 63c4 | 0.18 | 1400 | IEC 63 | Single-phase | 1.5 at 230 V | 4 pumps | |
| RN 63c4 uprated | 0.25 | 1360 | IEC 63 | IE1 | 0.82 | 9 pumps | |
| RN 71a4 | 0.25 | 1400 | IEC 71 | IE1 | 0.8 | 9 pumps | |
| RNM 71a4 | 0.25 | 1380 | IEC 71 | Single-phase | 2.65 at 230 V | 9 pumps | |
| RN 71b4 | 0.37 | 1410 | IEC 71 | IE1 | 1.2 | 0 pumps | |
| RNM 71b4 | 0.37 | 1400 | IEC 71 | Single-phase | 3.5 at 230 V | 0 pumps | |
| RN 71c4 uprated | 0.55 | 1370 | IEC 71 | IE1 | 1.7 | 17 pumps | |
| RN 80a4 | 0.55 | 1420 | IEC 80 | IE1 | 1.5 | 17 pumps | |
| RNM 71c4 | 0.55 | 1390 | IEC 71 | Single-phase | 5.2 at 230 V | 17 pumps | |
| RNM 80a4 | 0.55 | 1420 | IEC 80 | Single-phase | 4.8 at 230 V | 17 pumps | |
| RN 80b4 | 0.75 | 1400 | IEC 80 | IE1 | 2 | 6 pumps | |
| RNE 80b4 | 0.75 | 1435 | IEC 80 | IE3 | 1.8 | 6 pumps | |
| RNM 80b4 | 0.75 | 1420 | IEC 80 | Single-phase | 6.2 at 230 V | 6 pumps | |
| RN 80c4 uprated | 1 | 1380 | IEC 80 | IE1 | 2.5 | 17 pumps | |
| RNM 80c4 | 1 | 1410 | IEC 80 | Single-phase | 6.8 at 230 V | 17 pumps | |
| RN 90Sa4 | 1.1 | 1410 | IEC 90S | IE1 | 2.7 | 25 pumps | |
| RNE 90Sa4 | 1.1 | 1440 | IEC 90S | IE3 | 2.5 | 25 pumps | |
| RNM 90Sa4 | 1.1 | 1420 | IEC 90S | Single-phase | 8.5 at 230 V | 8 pumps | |
| RN 90La4 | 1.5 | 1410 | IEC 90L | IE1 | 3.6 | 15 pumps | |
| RNE 90La4 | 1.5 | 1430 | IEC 90L | IE3 | 3.6 | 15 pumps | |
| RNM 90La4 | 1.5 | 1410 | IEC 90L | Single-phase | 10.5 at 230 V | 15 pumps | |
| RN 90Lb4 uprated | 1.85 | 1410 | IEC 90L | IE1 | 4.3 | 16 pumps | |
| RNM 90Lb4 | 1.85 | 1390 | IEC 90L | Single-phase | 13.2 at 230 V | 16 pumps | |
| RN 100a4 | 2.2 | 1420 | IEC 100 | IE1 | 4.9 | 87 pumps | |
| RN 90Lc4 uprated | 2.2 | 1400 | IEC 90L | IE1 | 5.4 | 71 pumps | |
| RNE 100a4 | 2.2 | 1455 | IEC 100 | IE3 | 5.9 | 87 pumps | |
| RNM 100a4 | 2.2 | 1430 | IEC 100 | Single-phase | 14 at 230 V | 71 pumps | |
| RNM 112a4 | 2.2 | 1450 | IEC 112 | Single-phase | 12.5 at 230 V | 71 pumps | |
| RNM 90Lc4 | 2.2 | 1370 | IEC 90L | Single-phase | 14.5 at 230 V | 71 pumps | |
| RNM 100b4 | 2.6 | 1430 | IEC 100 | Single-phase | 15.5 at 230 V | 30 pumps | |
| RNM 112b4 | 2.6 | 1400 | IEC 112 | Single-phase | 15 at 230 V | 30 pumps | |
| RN 100b4 | 3 | 1420 | IEC 100 | IE1 | 6.4 | 83 pumps | |
| RNE 100b4 | 3 | 1440 | IEC 100 | IE3 | 6.8 | 83 pumps | |
| RNM 100c4 | 3 | 1410 | IEC 100 | Single-phase | 17 at 230 V | 53 pumps | |
| RNM 112c4 | 3 | 1415 | IEC 112 | Single-phase | 18.5 at 230 V | 53 pumps | |
| RN 100c4 uprated | 4 | 1405 | IEC 100 | IE1 | 9.1 | 235 pumps | |
| RN 112a4 | 4 | 1430 | IEC 112 | IE1 | 8.5 | 235 pumps | |
| RNE 112a4 | 4 | 1450 | IEC 112 | IE3 | 8.2 | 235 pumps | |
| RNM 112d4 | 4 | 1400 | IEC 112 | Single-phase | 22 at 230 V | 235 pumps | |
| RN 112b4 uprated | 5.5 | 1420 | IEC 112 | IE1 | 12.2 | 266 pumps | |
| RN 132Sa4 | 5.5 | 1430 | IEC 132S | IE1 | 11.4 | 266 pumps | |
| RNE 132Sa4 | 5.5 | 1450 | IEC 132S | IE3 | 10.6 | 266 pumps | |
| RN 112c4 uprated | 6.3 | 1420 | IEC 112 | IE1 | 12.5 | 104 pumps | |
| RN 132Ma4 | 7.5 | 1440 | IEC 132M | IE1 | 15.3 | 212 pumps | |
| RNE 132Ma4 | 7.5 | 1465 | IEC 132M | IE3 | 15.3 | 212 pumps | |
| RN 132Mb4 uprated | 9.2 | 1440 | IEC 132M | IE1 | 19.2 | 135 pumps | |
| RN 132Mc4 uprated | 11 | 1430 | IEC 132M | IE1 | 24 | 111 pumps | |
| RN 160Ma4 | 11 | 1450 | IEC 160M | IE1 | 22.4 | 246 pumps | |
| RNE 160Ma4 | 11 | 1475 | IEC 160M | IE3 | 22.4 | 246 pumps | |
| RN 160La4 | 15 | 1450 | IEC 160L | IE1 | 30 | 295 pumps | |
| RNE 160La4 | 15 | 1465 | IEC 160L | IE3 | 30.5 | 295 pumps | |
| RN 160Lb4 uprated | 18.5 | 1420 | IEC 160L | IE1 | 38 | 130 pumps | |
| RN 180Ma4 | 18.5 | 1465 | IEC 180M | IE1 | 37 | 130 pumps | |
| RN 160Lc4 uprated | 22 | 1450 | IEC 160L | IE1 | 42 | 73 pumps | |
| RN 180La4 | 22 | 1465 | IEC 180L | IE1 | 42 | 73 pumps | |
| RN 180Lb4 uprated | 30 | 1465 | IEC 180L | IE1 | 58 | 109 pumps | |
| RN 200a4 | 30 | 1475 | IEC 200 | IE1 | 57 | 109 pumps | |
| RN 200b4 | 37 | 1475 | IEC 200 | IE1 | 71 | 35 pumps | |
| RN 63a6 | 0.09 | 860 | IEC 63 | IE1 | 0.52 | 0 pumps | |
| RNM 71a6 | 0.11 | 865 | IEC 71 | Single-phase | 1.2 at 230 V | 0 pumps | |
| RN 63b6 | 0.12 | 860 | IEC 63 | IE1 | 0.65 | 0 pumps | |
| RNM 71b6 | 0.15 | 870 | IEC 71 | Single-phase | 1.7 at 230 V | 0 pumps | |
| RN 71a6 | 0.18 | 865 | IEC 71 | IE1 | 0.85 | 0 pumps | |
| RN 71b6 | 0.25 | 870 | IEC 71 | IE1 | 0.95 | 0 pumps | |
| RNM 80a6 | 0.25 | 880 | IEC 80 | Single-phase | 2.4 at 230 V | 0 pumps | |
| RN 71c6 uprated | 0.37 | 870 | IEC 71 | IE1 | 1.15 | 0 pumps | |
| RN 80a6 | 0.37 | 900 | IEC 80 | IE1 | 1.3 | 0 pumps | |
| RNM 80b6 | 0.37 | 885 | IEC 80 | Single-phase | 3.5 at 230 V | 0 pumps | |
| RN 80b6 | 0.55 | 905 | IEC 80 | IE1 | 1.9 | 0 pumps | |
| RNM 80c6 | 0.55 | 880 | IEC 80 | Single-phase | 4.4 at 230 V | 0 pumps | |
| RNM 90Sa6 | 0.55 | 870 | IEC 90S | Single-phase | 4.6 at 230 V | 0 pumps | |
| RN 90Sa6 | 0.75 | 900 | IEC 90S | IE1 | 2.2 | 0 pumps | |
| RNM 90La6 | 0.75 | 890 | IEC 90L | Single-phase | 6 at 230 V | 0 pumps | |
| RN 90La6 | 1.1 | 910 | IEC 90L | IE1 | 3.1 | 0 pumps | |
| RNM 100a6 | 1.1 | 895 | IEC 100 | Single-phase | 8.2 at 230 V | 0 pumps | |
| RNM 100b6 | 1.35 | 895 | IEC 100 | Single-phase | 9.5 at 230 V | 0 pumps | |
| RN 100a6 | 1.5 | 925 | IEC 100 | IE1 | 4.2 | 0 pumps | |
| RN 100b6 uprated | 2.2 | 915 | IEC 100 | IE1 | 5.7 | 0 pumps | |
| RN 112a6 | 2.2 | 940 | IEC 112 | IE1 | 5.9 | 0 pumps | |
| RN 112b6 uprated | 3 | 935 | IEC 112 | IE1 | 7.8 | 3 pumps | |
| RN 132Sa6 | 3 | 945 | IEC 132S | IE1 | 7.9 | 3 pumps | |
| RN 132Ma6 | 4 | 950 | IEC 132M | IE1 | 9.7 | 7 pumps | |
| RN 132Mb6 uprated | 5.5 | 960 | IEC 132M | IE1 | 13.1 | 26 pumps | |
| RN 160Ma6 | 7.5 | 965 | IEC 160M | IE1 | 18.1 | 48 pumps | |
| RN 160La6 | 11 | 965 | IEC 160L | IE1 | 24.3 | 10 pumps | |
| RN 180La6 | 15 | 970 | IEC 180L | IE1 | 32 | 29 pumps | |
| RN 200a6 | 18.5 | 985 | IEC 200 | IE1 | 38 | 16 pumps | |
| RN 200b6 | 22 | 980 | IEC 200 | IE1 | 44 | 15 pumps | |
| RN 71a8 | 0.09 | 630 | IEC 71 | IE1 | 0.38 | 0 pumps | |
| RN 71b8 | 0.12 | 640 | IEC 71 | IE1 | 0.5 | 0 pumps | |
| RN 80a8 | 0.18 | 675 | IEC 80 | IE1 | 0.9 | 0 pumps | |
| RN 80b8 | 0.25 | 670 | IEC 80 | IE1 | 1.12 | 0 pumps | |
| RN 90Sa8 | 0.37 | 680 | IEC 90S | IE1 | 1.25 | 0 pumps | |
| RN 90La8 | 0.55 | 690 | IEC 90L | IE1 | 1.95 | 0 pumps | |
| RN 100a8 | 0.75 | 695 | IEC 100 | IE1 | 2.2 | 0 pumps | |
| RN 100b8 | 1.1 | 700 | IEC 100 | IE1 | 3.1 | 0 pumps | |
| RN 112a8 | 1.5 | 705 | IEC 112 | IE1 | 4.4 | 0 pumps | |
| RN 112b8 uprated | 1.85 | 700 | IEC 112 | IE1 | 5.4 | 0 pumps | |
| RN 132Sa8 | 2.2 | 700 | IEC 132S | IE1 | 6.1 | 0 pumps | |
| RN 132Ma8 | 3 | 710 | IEC 132M | IE1 | 8.3 | 0 pumps | |
| RN 132Mb8 uprated | 3.7 | 710 | IEC 132M | IE1 | 9.9 | 0 pumps | |
| RN 160Ma8 | 4 | 710 | IEC 160M | IE1 | 10.5 | 0 pumps | |
| RN 160Mb8 | 5.5 | 715 | IEC 160M | IE1 | 14.2 | 0 pumps | |
| RN 160La8 | 7.5 | 720 | IEC 160L | IE1 | 18.5 | 5 pumps | |
| RN 180La8 | 11 | 720 | IEC 180L | IE1 | 24.5 | 0 pumps | |
| RN 200a8 | 15 | 740 | IEC 200 | IE1 | 30 | 0 pumps |
No motor matches. A pump with no motor here may need more power than the largest motor of its speed, or a hollow-shaft motor.