PumpLookupPump and motor part numbers
Mains Units

three-phase motor, IE1

RN 160Ma6

  • 7.5Power, kW
  • 965Speed, rpm
  • 6Poles
  • 160MIEC frame
  • 18.1Amps at 400 V
Nicolini three-phase motor

Specification

Rated output
7.5 kW
Speed
965 rpm (6-pole)
Supply
230/400 V 50 Hz, three-phase. Also wound for 60 Hz and other voltages to order; the figures here are at 50 Hz.
Current at 400 V
18.1 A
Efficiency
84%, IE1
Power factor
0.75
Starting current
5.7 × rated
Torque
74 Nm
Frame
IEC 160M
Shaft end
42 × 110 mm
Large flange (B5)
FF300
Small flange (B14)
None for this frame
Weight (B3)
80 kg

Pumps it drives

Pumps rated at this motor's speed that need no more than 7.5 kW, where this is the smallest motor that does the job.

Hawk NMT 4

NMT1220SLNMT1220SRNMT1520SLNMT1520SR

Hawk NMT Car Wash 4

NMT1220SCWLNMT1220SCWRNMT1520SCWLNMT1520SCWR

Hawk NMT High Temperature 2

NMT1520SHTLNMT1520SHTR

Hawk NMT nickel-plated 4

NMT1220SLNNMT1220SRNNMT1520SLNNMT1520SRN

Udor BCW 3

BCWB 11/20 SBCWB 13/20 SBCWB 15/20 S

Interpump 47 series 5

W131W132W151W162W201

Interpump 59 E3 series 4

E3A1515E3A1713E3A2113E3A2115

Mazzoni MMD 2

MMD15250L (1000 rpm)MMD15250R (1000 rpm)

Mazzoni MMD-CW 2

MMD-CW15250L (1000 rpm)MMD-CW15250R (1000 rpm)

Mazzoni MMX 2

MMX15200L (1000 rpm)MMX15200R (1000 rpm)

Mazzoni TMM high temperature 2

TMM15200L (1000 rpm)TMM15200R (1000 rpm)

Cat Pumps 5 Frame 4

310310B310S311

Cat Pumps 5CP 2

5CP2120B5CP2120W

Cat Pumps 7 Frame 1

530

Annovi Reverberi CWX 1

CWX 15.17 N code 20472

Annovi Reverberi XWF 3

XWF 26.12 N code 21051XWF 26.15 N code 21052XWF 30.10 N code 21054

Annovi Reverberi XWL-SS 1

XWL-SS 33.08 N

Comet RWN 2

RWN 4030 SRWN 4530 S

Flanges and couplings

For an IEC 160 frame with a 42 mm shaft, bolting to the large flange (B5). Pick the one made for your pump series.

Part numberDescriptionFor pump series
1.099-532.0Hawk motor flange, IEC 160 B5XLTI, XLTI High Temperature, PXI 350, XXT, XLTI Atex, PXI 500, XXT High Temperature, XLTI Chemical, XLTI Stainless Steel Chemical, PXI Heavy Duty
C14Udor motor flange C14, IEC 160 B3/B5, up to 15 kWC, CS, CWT, CK, CX, CH
NK01Udor motor flange NK01, IEC 160 B3/B5, up to 15 kWNK, NKS, NH
1.905-878.0Hawk flexible coupling, IEC 160, 42 mm motor to 30 mm pumpMXT, MXT High Temperature, MPX 350, MPX 500, MXT Chemical, MPX Heavy Duty, MXT Stainless Steel Chemical, MXT High Flow
1.905-890.0Hawk flexible coupling, IEC 160, 42 mm motor to 24 mm pumpXLTI, XLTI High Temperature, PXI 350, XXT, XLTI Atex, PXI 500, XXT High Temperature, XLTI Chemical, XLTI Stainless Steel Chemical, PXI Heavy Duty
ZG66160Interpump flexible coupling, IEC 160, 42 mm motor shaft47, 47VHT, 66, 66VHT, 66SS, E3, C3W and SS3

Starter

Iskra parts for a direct-on-line starter at 400 V. Choose the contactor coil to match your control voltage.

Contactor

KNL16 contactors, rated 7.5 kW AC-3 at 400 V

CoilTypeIskra codeSuppliers
12 V ACKNL16-10 1NO030050678000 
24 V AC B7KNL16-01 1NC030050665000 
24 V AC B7KNL16-10 1NO030050666000 
42 V AC D7KNL16-01 1NC030050667000 
42 V AC D7KNL16-10 1NO030050668000 
48 V AC E7KNL16-01 1NC030050669000 
48 V AC E7KNL16-10 1NO030050670000 
110-125 V AC F7KNL16-01 1NC030050671000 
110-125 V AC F7KNL16-10 1NO030050672000 
220-240 V AC M7KNL16-01 1NC030050673000 
220-240 V AC M7KNL16-10 1NO030050489000 
380-415 V AC Q7KNL16-01 1NC030050674000 
380-415 V AC Q7KNL16-10 1NO030050675000 
440-460 V AC R7KNL16-10 1NO030050921000 
480-520 V AC S7KNL16-01 1NC030050676000 
480-520 V AC S7KNL16-10 1NO030050677000 

Overload protection

Set to the motor's full-load current, 18.1 A.

Other motors in this range

RN 63a6RN 63b6RN 71a6RN 71b6RN 71c6RN 80a6RN 80b6RN 90La6RN 90Sa6RN 100a6RN 100b6RN 112a6RN 112b6RN 132Ma6RN 132Mb6RN 132Sa6RN 160La6RN 180La6RN 200a6RN 200b6