three-phase motor, IE1
RN 132Mb6
uprated
- 5.5Power, kW
- 960Speed, rpm
- 6Poles
- 132MIEC frame
- 13.1Amps at 400 V

Specification
- Rated output
- 5.5 kW
- Speed
- 960 rpm (6-pole)
- Supply
- 230/400 V 50 Hz, three-phase. Also wound for 60 Hz and other voltages to order; the figures here are at 50 Hz.
- Current at 400 V
- 13.1 A
- Efficiency
- 84%, IE1
- Power factor
- 0.76
- Starting current
- 6.4 × rated
- Torque
- 55 Nm
- Frame
- IEC 132M
- Shaft end
- 38 × 80 mm
- Large flange (B5)
- FF265
- Small flange (B14)
- FT165
- Weight (B3)
- 53 kg
Uprated: Nicolini mark this power as one IEC does not list for the frame. It gives more power in a smaller frame, at lower efficiency.
Pumps it drives
Pumps rated at this motor's speed that need no more than 5.5 kW, where this is the smallest motor that does the job.
Hawk NMT 2
Hawk NMT Car Wash 2
Hawk NMT High Temperature 2
Hawk NMT nickel-plated 2
Udor BCW 2
Interpump 47 series 3
Interpump 59 E3 series 3
Cat Pumps 5 Frame 4
Cat Pumps 5CP 2
Annovi Reverberi CWX 1
Annovi Reverberi XWF 2
XWF 26.12 N code 21051XWF 30.10 N code 21054
Annovi Reverberi XWL-SS 1
Flanges and couplings
For an IEC 132 frame with a 38 mm shaft, bolting to the small flange (B14). Pick the one made for your pump series.
| Part number | Description | For pump series |
|---|---|---|
| 1.099-531.0 | Hawk motor flange, IEC 132 B14 | NMT, NPM, NMT Car Wash, NMT High Temperature, NMT Nickel-Plated, NPM Nickel-Plated, XLTI, XLTI High Temperature, PXI 350, XXT, NLTI, XLTI Atex, PXI 500, NMT - Car Wash Heavy Duty, NMT Chemical, XLTI Chemical, XLTI Stainless Steel Chemical, NMT Stainless Steel Chemical, PXI Heavy Duty |
| BC10 | Udor motor flange BC10, IEC 132 B3/B14, up to 11 kW | B, BS, BCW, BWT, BK, C, CS, CWT, CK, CX, CH |
| ZF132 | Interpump motor flange, IEC 132 B14 | 47, 47VHT, 66, 66VHT, 66SS, E3, C3W and SS3 |
| 1.099-545.0 | Hawk flexible coupling, IEC 132, 38 mm motor to 24 mm pump | NMT, NPM, NMT Car Wash, NMT High Temperature, NMT Nickel-Plated, NPM Nickel-Plated, XLTI, XLTI High Temperature, PXI 350, XXT, NLTI, XLTI Atex, PXI 500, NMT - Car Wash Heavy Duty, NMT Chemical, XLTI Chemical, XLTI Stainless Steel Chemical, NMT Stainless Steel Chemical, PXI Heavy Duty |
| ZG132 | Interpump flexible coupling, IEC 132, 38 mm motor to 24 mm pump | 47, 47VHT, 66, 66VHT, 66SS, E3, C3W and SS3 |
Starter
Iskra parts for a direct-on-line starter at 400 V. Choose the contactor coil to match your control voltage.
Contactor
KNL12 contactors, rated 5.5 kW AC-3 at 400 V
| Coil | Type | Iskra code | Suppliers |
|---|---|---|---|
| 24 V AC B7 | KNL12-01 1NC | 030050648000 | |
| 24 V AC B7 | KNL12-10 1NO | 030050649000 | |
| 42 V AC D7 | KNL12-01 1NC | 030050650000 | |
| 42 V AC D7 | KNL12-10 1NO | 030050651000 | |
| 48 V AC E7 | KNL12-01 1NC | 030050652000 | |
| 48 V AC E7 | KNL12-10 1NO | 030050653000 | |
| 110-125 V AC F7 | KNL12-01 1NC | 030050654000 | |
| 110-125 V AC F7 | KNL12-10 1NO | 030050655000 | |
| 220-240 V AC M7 | KNL12-01 1NC | 030050656000 | |
| 220-240 V AC M7 | KNL12-10 1NO | 030050488000 | |
| 380-415 V AC Q7 | KNL12-01 1NC | 030050657000 | |
| 380-415 V AC Q7 | KNL12-10 1NO | 030050658000 | |
| 440-460 V AC R7 | KNL12-01 1NC | 030050920000 | |
| 440 V AC R7 | KNL12-10 1NO | 030050911000 | |
| 480-520 V AC S7 | KNL12-01 1NC | 030050659000 | |
| 480-520 V AC S7 | KNL12-10 1NO | 030050660000 |
Overload protection
Set to the motor's full-load current, 13.1 A.
Other motors in this range
RN 63a6RN 63b6RN 71a6RN 71b6RN 71c6RN 80a6RN 80b6RN 90La6RN 90Sa6RN 100a6RN 100b6RN 112a6RN 112b6RN 132Ma6RN 132Sa6RN 160La6RN 160Ma6RN 180La6RN 200a6RN 200b6