three-phase motor, IE3
RNE 90La2
- 2.2Power, kW
- 2880Speed, rpm
- 2Poles
- 90LIEC frame
- 4.6Amps at 400 V

Specification
- Rated output
- 2.2 kW
- Speed
- 2880 rpm (2-pole)
- Supply
- 230/400 V 50 Hz, three-phase. Also wound for 60 Hz and other voltages to order; the figures here are at 50 Hz.
- Current at 400 V
- 4.6 A
- Efficiency
- 86.5%, IE3
- Power factor
- 0.82
- Starting current
- 9.2 × rated
- Torque
- 7.3 Nm
- Frame
- IEC 90L
- Shaft end
- 24 × 50 mm
- Large flange (B5)
- FF165
- Small flange (B14)
- FT115
- Weight (B3)
- 16 kg
Pumps it drives
Pumps rated at this motor's speed that need no more than 2.2 kW, where this is the smallest motor that does the job.
Udor PN 1
Interpump 51 series 8
TT931TT941TT951TT1508WW93WW94WW95WW1508
Annovi Reverberi HJRS 1
Annovi Reverberi JRS 5
JRS 8.14 N TAJRS 8.14 N TSS TAJRS 8.15 NJRS 8.15 N TSSJRS 10.12 N
Annovi Reverberi JRV 1
Annovi Reverberi RCS 1
Annovi Reverberi RMV 1
Annovi Reverberi RMW 1
Annovi Reverberi RPV 1
Annovi Reverberi RPW 1
Annovi Reverberi XJS 2
XJS 8.15 C code 20484XJS 8.15 N
Annovi Reverberi XTS 2
Annovi Reverberi XTV 1
Bertolini WBL 6
WBL 812-FWBL 814-FWBL 1010-FWBL 1012-FWBL 1110-FWBL 1309-F
Bertolini WBS 3
Flanges and couplings
For an IEC 90 frame with a 24 mm shaft, bolting to the small flange (B14). Pick the one made for your pump series.
| Part number | Description | For pump series |
|---|---|---|
| 1.099-528.0 | Hawk motor flange, IEC 90 B14 | NHDP Car Wash, NHDP 120, NHDP 150, NHDP 200, NHDP Chemical, NHDP Stainless Steel Chemical |
| 1.099-534.0 | Hawk motor flange, IEC 90 B14 | CHS 120 |
| ZF070 | Interpump motor flange, IEC 90 B14 | E1, SS1, 44, 58VHT, E2, C2W, 50 and 51 |
| 1.099-542.0 | Hawk flexible coupling, IEC 90, 24 mm motor to 24 mm pump | NHDP Car Wash, NHDP 120, NHDP 150, NHDP 200, NHDP Chemical, NHDP Stainless Steel Chemical, CHD 200, CHS 120 |
| 1.099-544.0 | Hawk flexible coupling, IEC 90, 24 mm motor to 24 mm pump | NMT, NMT Car Wash, NMT High Temperature, NMT Nickel-Plated, NMT - Car Wash Heavy Duty, NMT Chemical, NMT Stainless Steel Chemical |
| ZG070 | Interpump flexible coupling, IEC 90, 24 mm motor to 24 mm pump | E1, SS1, 44, 58VHT, E2, C2W and 50 |
| ZGWW75 | Interpump flexible coupling, IEC 90, 24 mm motor to 24 mm pump | 51 |
Starter
Iskra parts for a direct-on-line starter at 400 V. Choose the contactor coil to match your control voltage.
Contactor
KNL9 contactors, rated 4 kW AC-3 at 400 V
| Coil | Type | Iskra code | Suppliers |
|---|---|---|---|
| 24 V AC B7 | KNL9-01 1NC | 030050615000 | |
| 24 V AC B7 | KNL9-10 1NO | 030050616000 | |
| 42 V AC D7 | KNL9-01 1NC | 030050633000 | |
| 42 V AC D7 | KNL9-10 1NO | 030050634000 | |
| 48 V AC E7 | KNL9-01 1NC | 030050635000 | |
| 48 V AC E7 | KNL9-10 1NO | 030050636000 | |
| 110-125 V AC F7 | KNL9-01 1NC | 030050637000 | |
| 110-125 V AC F7 | KNL9-10 1NO | 030050638000 | |
| 208 V AC | KNL9-01 1NC | 030050819000 | |
| 220-240 V AC M7 | KNL9-01 1NC | 030050475000 | |
| 220-240 V AC M7 | KNL9-10 1NO | 030050474000 | |
| 380-415 V AC Q7 | KNL9-01 1NC | 030050639000 | |
| 380-415 V AC Q7 | KNL9-10 1NO | 030050640000 | |
| 440-460 V AC R7 | KNL9-10 1NO | 030050919000 | |
| 480-520 V AC S7 | KNL9-01 1NC | 030050641000 | |
| 480-520 V AC S7 | KNL9-10 1NO | 030050642000 |
Overload protection
Set to the motor's full-load current, 4.6 A.