PumpLookupPump and motor part numbers
Mains Units

three-phase motor, IE3

RNE 100a2

  • 3Power, kW
  • 2900Speed, rpm
  • 2Poles
  • 100IEC frame
  • 5.6Amps at 400 V
Nicolini three-phase motor

Specification

Rated output
3 kW
Speed
2900 rpm (2-pole)
Supply
230/400 V 50 Hz, three-phase. Also wound for 60 Hz and other voltages to order; the figures here are at 50 Hz.
Current at 400 V
5.6 A
Efficiency
87.1%, IE3
Power factor
0.89
Starting current
8.8 × rated
Torque
9.9 Nm
Frame
IEC 100
Shaft end
28 × 60 mm
Large flange (B5)
FF215
Small flange (B14)
FT130
Weight (B3)
22.8 kg

Pumps it drives

Pumps rated at this motor's speed that need no more than 3 kW, where this is the smallest motor that does the job.

Hawk NHDP 200-NEMA 2

NHDP2030FNELNHDP2030FNER

Udor PN 2

PNE 11/14 SPNL 2.5/20 T

Interpump 44 series 1

WW116

Interpump 51 series 6

TT1510TT1511TT9091WW909WW1509WW1510

Interpump 53 E1 series 3

E1D1807E1D1808E1E1808

Interpump 53 ET1 brass series 3

ET1D1807ET1D1808ET1E1808

Annovi Reverberi JRS 4

JRS 10.14 N TAJRS 10.14 N TSS TAJRS 10.15 NJRS 10.15 N TSS

Annovi Reverberi JRV 1

JRV 3G20 D TA + F7

Annovi Reverberi RMV 2

RMV 2 G23 DRMV 2.2 G24 D

Annovi Reverberi RMW 2

RMW 2 G23 DRMW 2.2 G24 D

Annovi Reverberi RSS 2

RSS 11.14 C+F16RSS 11.14 N

Annovi Reverberi SJS 1

SJS 8.17 N

Annovi Reverberi SJV 1

SJV 2 G25 D + F7

Annovi Reverberi XJS 5

XJS 10.15 C code 20441XJS 10.15 NXJS 11.14 + F39XJS 11.14 C code 20442XJS 11.14 N

Annovi Reverberi XTS 3

XTS 10.15 NXTS 11.14 CXTS 13.12 C

Comet LWR-K 1

LWR-K 3020 S

Bertolini WBL 4

WBL 1016-FWBL 1114-FWBL 1312-FWBL 1410-F

Bertolini WBS 1

WBS 1735-F

Bertolini WML 1

WML 1114-F

Flanges and couplings

For an IEC 100 frame with a 28 mm shaft, bolting to the small flange (B14). Pick the one made for your pump series.

Part numberDescriptionFor pump series
1.099-529.0Hawk motor flange, IEC 100/112 B14NHDP Car Wash, NHDP 120, NHDP 150, NHDP 200, NHDP Chemical, NHDP Stainless Steel Chemical
1.099-530.0Hawk motor flange, IEC 100/112 B14NMT, NPM, NMT Car Wash, NMT High Temperature, NMT Nickel-Plated, NPM Nickel-Plated, NLTI, NMT - Car Wash Heavy Duty, NMT Chemical, NMT Stainless Steel Chemical, CHD 200, CHS 120
A08Udor motor flange A08, IEC 100/112 B3/B14, up to 4 kWA, AK, AWT
BC04Udor motor flange BC04, IEC 100/112 B3/B14, up to 4 kWB, BS, BCW, BWT, BK, C, CS, CWT, CK, CX, CH
P05Udor motor flange P05, IEC 100/112 B3/B14, up to 4 kWPN, PS
ZF044Interpump motor flange, IEC 100/112 B14E1, SS1, 44, 58VHT, E2 and C2W
ZF091Interpump motor flange, IEC 100/112 B1449, 50 and 51
ZF151Interpump motor flange, IEC 100/112 B1447, 47VHT, 66, 66VHT, 66SS, E3, C3W and SS3
1.099-541.0Hawk flexible coupling, IEC 100/112, 28 mm motor to 24 mm pumpNMT, NPM, NMT Car Wash, NMT High Temperature, NMT Nickel-Plated, NPM Nickel-Plated, XLTI, XLTI High Temperature, NLTI, XLTI Atex, NMT - Car Wash Heavy Duty, NMT Chemical, NMT Stainless Steel Chemical, CHD 200, CHS 120
1.099-543.0Hawk flexible coupling, IEC 100/112, 28 mm motor to 24 mm pumpNHDP Car Wash, NHDP 120, NHDP 150, NHDP 200, NHDP Chemical, NHDP Stainless Steel Chemical
ZG044Interpump flexible coupling, IEC 100/112, 28 mm motor to 24 mm pumpE1, SS1, 44, 58VHT, E2 and C2W
ZG091Interpump flexible coupling, IEC 100/112, 28 mm motor to 24 mm pump49 and 50
ZG151Interpump flexible coupling, IEC 100/112, 28 mm motor to 24 mm pump47, 47VHT, 66, 66VHT, 66SS, E3, C3W and SS3
ZGWW94Interpump flexible coupling, IEC 100/112, 28 mm motor to 24 mm pump51

Starter

Iskra parts for a direct-on-line starter at 400 V. Choose the contactor coil to match your control voltage.

Contactor

KNL9 contactors, rated 4 kW AC-3 at 400 V

CoilTypeIskra codeSuppliers
24 V AC B7KNL9-01 1NC030050615000 
24 V AC B7KNL9-10 1NO030050616000 
42 V AC D7KNL9-01 1NC030050633000 
42 V AC D7KNL9-10 1NO030050634000 
48 V AC E7KNL9-01 1NC030050635000 
48 V AC E7KNL9-10 1NO030050636000 
110-125 V AC F7KNL9-01 1NC030050637000 
110-125 V AC F7KNL9-10 1NO030050638000 
208 V ACKNL9-01 1NC030050819000 
220-240 V AC M7KNL9-01 1NC030050475000 
220-240 V AC M7KNL9-10 1NO030050474000 
380-415 V AC Q7KNL9-01 1NC030050639000 
380-415 V AC Q7KNL9-10 1NO030050640000 
440-460 V AC R7KNL9-10 1NO030050919000 
480-520 V AC S7KNL9-01 1NC030050641000 
480-520 V AC S7KNL9-10 1NO030050642000 

Overload protection

Set to the motor's full-load current, 5.6 A.

Other motors in this range

RNE 80a2RNE 80b2RNE 90La2RNE 90Sa2RNE 112a2RNE 132Sa2RNE 132Sb2RNE 160La2RNE 160Ma2RNE 160Mb2