three-phase motor, IE1
RN 112c2
uprated
- 7.5Power, kW
- 2860Speed, rpm
- 2Poles
- 112IEC frame
- 15.5Amps at 400 V

Specification
- Rated output
- 7.5 kW
- Speed
- 2860 rpm (2-pole)
- Supply
- 230/400 V 50 Hz, three-phase. Also wound for 60 Hz and other voltages to order; the figures here are at 50 Hz.
- Current at 400 V
- 15.5 A
- Efficiency
- 81.3%, IE1
- Power factor
- 0.86
- Starting current
- 7.4 × rated
- Torque
- 25.1 Nm
- Frame
- IEC 112
- Shaft end
- 28 × 60 mm
- Large flange (B5)
- FF215
- Small flange (B14)
- FT130
- Weight (B3)
- 34 kg
Uprated: Nicolini mark this power as one IEC does not list for the frame. It gives more power in a smaller frame, at lower efficiency.
Pumps it drives
Pumps rated at this motor's speed that need no more than 7.5 kW, where this is the smallest motor that does the job.
Hawk NHDP 200 2
Hawk NPM-GR 1
Interpump 44 series 8
WW176WW189WW206WW209WW962WW966WW967WW968
Interpump 53 E1 series 3
Interpump 58 E2 series 8
E2D2015E2D2016E2D2811E2D2812E2D2813E2E2116E2E2812E2E2813
Interpump 59 E3 series 1
Mazzoni MMD-EDM-E4 2
MMD-EDM E4 13275LMMD-EDM E4 13275R
Mazzoni PM-EDM-E4 2
PM-EDM E4 15200LPM-EDM E4 15200R
Annovi Reverberi RKV 1
Annovi Reverberi RRV 2
RRV 3.5G36 D + flange ø 1”RRV 4G36 D + flange ø 1”
Annovi Reverberi RSV 2
RSV 3.5G35 D+F40RSV 4G35 D+F40
Annovi Reverberi SXMV 4
SXMV 3.5G35 D+F40SXMV 3.5G35 NSXMV 4G35 D+F40 code 21264SXMV 4G35 N
Speck NP16 1
Flanges and couplings
For an IEC 112 frame with a 28 mm shaft, bolting to the small flange (B14). Pick the one made for your pump series.
| Part number | Description | For pump series |
|---|---|---|
| 1.099-529.0 | Hawk motor flange, IEC 100/112 B14 | NHDP Car Wash, NHDP 120, NHDP 150, NHDP 200, NHDP Chemical, NHDP Stainless Steel Chemical |
| 1.099-530.0 | Hawk motor flange, IEC 100/112 B14 | NMT, NPM, NMT Car Wash, NMT High Temperature, NMT Nickel-Plated, NPM Nickel-Plated, NLTI, NMT - Car Wash Heavy Duty, NMT Chemical, NMT Stainless Steel Chemical, CHD 200, CHS 120 |
| ZF044 | Interpump motor flange, IEC 100/112 B14 | E1, SS1, 44, 58VHT, E2 and C2W |
| ZF091 | Interpump motor flange, IEC 100/112 B14 | 49, 50 and 51 |
| ZF151 | Interpump motor flange, IEC 100/112 B14 | 47, 47VHT, 66, 66VHT, 66SS, E3, C3W and SS3 |
| 1.099-541.0 | Hawk flexible coupling, IEC 100/112, 28 mm motor to 24 mm pump | NMT, NPM, NMT Car Wash, NMT High Temperature, NMT Nickel-Plated, NPM Nickel-Plated, XLTI, XLTI High Temperature, NLTI, XLTI Atex, NMT - Car Wash Heavy Duty, NMT Chemical, NMT Stainless Steel Chemical, CHD 200, CHS 120 |
| 1.099-543.0 | Hawk flexible coupling, IEC 100/112, 28 mm motor to 24 mm pump | NHDP Car Wash, NHDP 120, NHDP 150, NHDP 200, NHDP Chemical, NHDP Stainless Steel Chemical |
| ZG044 | Interpump flexible coupling, IEC 100/112, 28 mm motor to 24 mm pump | E1, SS1, 44, 58VHT, E2 and C2W |
| ZG091 | Interpump flexible coupling, IEC 100/112, 28 mm motor to 24 mm pump | 49 and 50 |
| ZG151 | Interpump flexible coupling, IEC 100/112, 28 mm motor to 24 mm pump | 47, 47VHT, 66, 66VHT, 66SS, E3, C3W and SS3 |
| ZGWW94 | Interpump flexible coupling, IEC 100/112, 28 mm motor to 24 mm pump | 51 |
Starter
Iskra parts for a direct-on-line starter at 400 V. Choose the contactor coil to match your control voltage.
Contactor
KNL16 contactors, rated 7.5 kW AC-3 at 400 V
| Coil | Type | Iskra code | Suppliers |
|---|---|---|---|
| 12 V AC | KNL16-10 1NO | 030050678000 | |
| 24 V AC B7 | KNL16-01 1NC | 030050665000 | |
| 24 V AC B7 | KNL16-10 1NO | 030050666000 | |
| 42 V AC D7 | KNL16-01 1NC | 030050667000 | |
| 42 V AC D7 | KNL16-10 1NO | 030050668000 | |
| 48 V AC E7 | KNL16-01 1NC | 030050669000 | |
| 48 V AC E7 | KNL16-10 1NO | 030050670000 | |
| 110-125 V AC F7 | KNL16-01 1NC | 030050671000 | |
| 110-125 V AC F7 | KNL16-10 1NO | 030050672000 | |
| 220-240 V AC M7 | KNL16-01 1NC | 030050673000 | |
| 220-240 V AC M7 | KNL16-10 1NO | 030050489000 | |
| 380-415 V AC Q7 | KNL16-01 1NC | 030050674000 | |
| 380-415 V AC Q7 | KNL16-10 1NO | 030050675000 | |
| 440-460 V AC R7 | KNL16-10 1NO | 030050921000 | |
| 480-520 V AC S7 | KNL16-01 1NC | 030050676000 | |
| 480-520 V AC S7 | KNL16-10 1NO | 030050677000 |
Overload protection
Set to the motor's full-load current, 15.5 A.
Other motors in this range