PumpLookupPump and motor part numbers
Mains Units

three-phase motor, IE1

RN 200b4

  • 37Power, kW
  • 1475Speed, rpm
  • 4Poles
  • 200IEC frame
  • 71Amps at 400 V
Nicolini three-phase motor

Specification

Rated output
37 kW
Speed
1475 rpm (4-pole)
Supply
230/400 V 50 Hz, three-phase. Also wound for 60 Hz and other voltages to order; the figures here are at 50 Hz.
Current at 400 V
71 A
Efficiency
89.7%, IE1
Power factor
0.84
Starting current
7.1 × rated
Torque
236 Nm
Frame
IEC 200
Shaft end
55 × 110 mm
Large flange (B5)
FF350
Small flange (B14)
None for this frame
Weight (B3)
205 kg

Pumps it drives

Pumps rated at this motor's speed that need no more than 37 kW, where this is the smallest motor that does the job.

Hawk HFR 2

HFR60FLHFR60FR

Hawk HHP 500 - 1450 rpm 2

HHP3650LHHP3650R

Udor NH 500 1

NH-C 30/500 R

Udor NK 12

NK-C 47/350 RNK-C 47/350 R MINK-C 55/300 RNK-C 55/300 R MINK-C 70/250 RNK-C 70/250 R MINK-C 130/130 RNK-C 130/130 R MINK-D 15.0/44 RNK-D 15.0/44 R MINK-D 27.0/25 RNK-D 27.0/25 R MI

Udor NK 500 1

NK-C 30/500 R

Udor PENTA 1

PENTA-C 58/300 R

Udor PENTA 600 2

PENTA-C 30/600 RPENTA-D 7.5/88 R

Mazzoni LM 2

LM67280LLM67280R

Mazzoni LMX 2

LMX36500LLMX36500R

Annovi Reverberi RTX 4

RTX 30.600NRTX 60.300 C DX+F56RTX 60.300 NRTX 60.300 N+F54

Annovi Reverberi RTX-I 2

RTX-I 24.800RTX-I 30.600 N

Bertolini CA 1

CA 2230

Bertolini CKL 2

CKL 2230.1CKL 2233.1

Bertolini RX 1

RX 3250

Flanges and couplings

For an IEC 200 frame with a 55 mm shaft, bolting to the large flange (B5). Pick the one made for your pump series.

Part numberDescriptionFor pump series
NK03Udor motor flange NK03, IEC 200 B3/B5, up to 37 kWNK, NKS, NH
VX02Udor motor flange VX02, IEC 200 B3/B5, up to 37 kWPENTA, VX, VXS, VH, VY
9.853-336.0Hawk flexible coupling, IEC 200, 55 mm motor to 30 mm pumpMXT, MXT High Temperature, MPX 350, MPX 500, MXT Chemical, MPX Heavy Duty, MXT Stainless Steel Chemical, MXT High Flow

Starter

Iskra parts for a direct-on-line starter at 400 V. Choose the contactor coil to match your control voltage.

Contactor

KNL75 contactors, rated 37 kW AC-3 at 400 V

CoilTypeIskra codeSuppliers
24 V AC B7KNL75-11 1NO+1NC030051104000 
110-125 V AC F7KNL75-11 1NO+1NC030051200000 
220-240 V AC M7KNL75-11 1NO+1NC030051103000 
380-415 V AC Q7KNL75-11 1NO+1NC030051102000 
480-500 V ACKNL75-11 1NO+1NC030051220000 

Overload protection

Set to the motor's full-load current, 71 A.

Other motors in this range

RN 63a4RN 63b4RN 63c4RN 71a4RN 71b4RN 71c4RN 80a4RN 80b4RN 80c4RN 90La4RN 90Lb4RN 90Lc4RN 90Sa4RN 100a4RN 100b4RN 100c4RN 112a4RN 112b4RN 112c4RN 132Ma4RN 132Mb4RN 132Mc4RN 132Sa4RN 160La4RN 160Lb4RN 160Lc4RN 160Ma4RN 180La4RN 180Lb4RN 180Ma4RN 200a4